COMPANY HEADER
Print Back
  • Ideally suited for Dual Active Bridge (DAB) or Phase Shifted Full Bridge (PSFB) Transformer applications
  • High efficiency and cost effective design and construction
  • Suggested Cooling: Heat Sink or 120LFM forced air
Unit of Measure

Electrical Parameters at 25 ºC

Input (VDC)

N/A 380-420

Output (VDC)

N/A 20-33

Maximum Output (ADC)

N/A 250

Switching Frequency

N/A 100 kHz

Maximum Output Power

N/A 7000 W

Minimum Primary Inductance

N/A 1800 µH

Maximum Leakage Inductance (1-2)

N/A 16.0 µH

Maximum Primary Direct Current Resistance (DCR)

N/A 20.0 mOhm

Maximum Secondary Direct Current Resistance (DCR)

N/A 0.50 mOhm

Primary : Secondary Turns Ratio (±3 %)

N/A 11:1

Specifications

Industry Standards / Certifications

N/A RoHS Compliant

Available Design

N/A custom

Standard Operating Temperature Range

N/A -40 to +125 ºC

Note

N/A

  1. Primary Inductance measured at 10kHz, 0.1Vrms
  2. Leakage inductance measured at 100kHz, 0.1Vrms (with all secondaries shorted)
  3. Polarity: 1 & 4 are in phase
  4. Hipot (1-2 to 3-4): 2KVrms, 1mA, 10s
  5. Hipot (wdgs to core): 2KVrms, 1mA, 10s
Product performance is limited to specified parameters. Data is subject to change without prior notice.

Dimensions
Unless otherwise specified, all tolerances are:
inch: .XX : ±0.010 .XXX : ±0.005
mm: X.X : ±0.254 X.XX : ±0.13