COMPANY HEADER
Print Back
  • High current inductor in compact size package (44 mm x 42 mm x 36 mm)
  • Inductance Range: 3.6 µH to 83 µH
  • Flat wire coil minimizes losses 
  • Vertical mount package with mounting clip and base for added support (horizontal mount version also available)
HWI4434V Series Helical Edge Wound (HEW) High Current Fixed Inductors
Unit of Measure
Items HWI4434V Series Helical Edge Wound (HEW) High Current Fixed Inductors
HWI4434-080A-140V
14 Microhenry (µH) Inductance (±15%) HWI4434V Series Helical Edge Wound (HEW) High Current Fixed Inductor
HWI4434V Series Helical Edge Wound (HEW) High Current Fixed Inductors
HWI4434-100A-8R4V
8.4 Microhenry (µH) Inductance (±15%) HWI4434V Series Helical Edge Wound (HEW) High Current Fixed Inductor
HWI4434V Series Helical Edge Wound (HEW) High Current Fixed Inductors
HWI4434-080A-6R0V
6 Microhenry (µH) Inductance (±15%) HWI4434V Series Helical Edge Wound (HEW) High Current Fixed Inductor
HWI4434V Series Helical Edge Wound (HEW) High Current Fixed Inductors
HWI4434-100A-5R6V
5.6 Microhenry (µH) Inductance (±15%) HWI4434V Series Helical Edge Wound (HEW) High Current Fixed Inductor
HWI4434V Series Helical Edge Wound (HEW) High Current Fixed Inductors
HWI4434-100A-3R6V
3.6 Microhenry (µH) Inductance (±15%) HWI4434V Series Helical Edge Wound (HEW) High Current Fixed Inductor
Inductance (±15%) N/A 14.0 µH N/A 8.4 µH N/A 6 µH N/A 5.6 µH N/A 3.6 µH
Irms (Typ) 20ºC rise N/A 52 A N/A 66 A N/A 52 A N/A 66 A N/A 66 A
Irms (Typ) 40ºC rise N/A 80 A N/A 100 A N/A 80 A N/A 100 A N/A 100 A
Maximum Direct Current (DC) Resistance N/A 1.1 mOhm N/A 0.7 mOhm N/A 1.1 mOhm N/A 0.7 mOhm N/A 0.7 mOhm
Isat (Typ) 10% drop N/A 50 A N/A 64 A N/A 112 A N/A 115 A N/A 143 A
Isat (Typ) 30% drop N/A 96 A N/A 124 A N/A 225 A N/A 207 A N/A 295 A
Standard Operating Temperature Range N/A -40 to 150 ºC
Note N/A
  • Inductance test @ 10 KHz, 1 Vrms
  • Isat is DC current at which the inductance drops the specified amount from its original value without bias.
  • Irms is the DC current that causes the specified temperature rise of the winding from 25ºC ambient for the inductor.
  • Add V for Vertical Mount, H for Horizontal Mount