COMPANY HEADER
Terms
  • Ideally suited for Dual Active Bridge (DAB) or Phase Shifted Full Bridge (PSFB) Transformer applications
  • High efficiency and cost effective design and construction
  • Suggested Cooling: Heat Sink or 120LFM forced air
Request Information
Unit of Measure
Items
E6520 Series Dual Active Bridge Transformer

E6526 Dual Active Bridge PSFB Transformer

E6520 Series Dual Active Bridge Transformer

E6527 Dual Active Bridge PSFB Transformer

E6520 Series Dual Active Bridge Transformer

E6528 Dual Active Bridge PSFB Transformer
Input (VDC) N/A 200-240 N/A 380-420 N/A 430-530
Output (VDC) N/A 20-33 N/A 20-33 N/A 33-56
Maximum Output (ADC) N/A 120 N/A 250 N/A 250
Switching Frequency N/A 100 kHz
Maximum Output Power N/A 3000 W N/A 7000 W N/A 10000 W
Minimum Primary Inductance N/A 1160 µH N/A 1800 µH N/A 1800 µH
Maximum Leakage Inductance (1-2) N/A 10.0 µH N/A 16.0 µH N/A 14.0 µH
Maximum Primary Direct Current Resistance (DCR) N/A 25.0 mOhm N/A 20.0 mOhm N/A 15.0 mOhm
Maximum Secondary Direct Current Resistance (DCR) N/A 1.00 mOhm N/A 0.50 mOhm N/A 0.50 mOhm
Primary : Secondary Turns Ratio (±3 %) N/A 7:1 N/A 11:1 N/A 9:1
Industry Standards / Certifications N/A RoHS Compliant
Available Design N/A custom
Standard Operating Temperature Range N/A -40 to +125 ºC
Note N/A
  1. Primary Inductance measured at 10kHz, 0.1Vrms
  2. Leakage inductance measured at 100kHz, 0.1Vrms (with all secondaries shorted)
  3. Polarity: 1 & 4 are in phase
  4. Hipot (1-2 to 3-4): 2KVrms, 1mA, 10s
  5. Hipot (wdgs to core): 2KVrms, 1mA, 10s
Product performance is limited to specified parameters. Data is subject to change without prior notice.

Dimensions
Unless otherwise specified, all tolerances are:
inch: .XX : ±0.010 .XXX : ±0.005
mm: X.X : ±0.254 X.XX : ±0.13